THOT PHASE II (1994) regional lines Survey Company: Enertec Geophysical Acquisition Company: Seismic Lines: S-1-A Directions: S-1-A (W to E) S-2-A, S-2-C (NE to SW) S-2-B, S-3-A, S-3-B (NW to SE) Source Type: Vibroseis, true reference in aux 2 SP/VP Interval: 100 m Sweep: 12-84 Hz Sweeps: 8 Sweep Length: 18 s Record Length/Sample Rate: 20 & 32 sec, 2 ms Source Pattern: 4 over 50 m Instrumentation: ARAM 24 Geophone Type: Mark L10A Frequency: 14 Hz Group Interval: 25 m Geophone Pattern: 9 over 25 m Spread Configuration: Traces: 1-------------160 * 161---------480 Distances:4125 150 150 8125 m