Abitibi-Grenville Transect, Phase II (1993) Uncorrelated, stacked data (except where problems with the stacker were encountered) were written to IBM 3480 BPI cartridges. The format is 2.5 byte demultiplexed SEGD. AG (1993) High resolution seismic lines 43, 44, 93A, 93D Survey Company: Enertec Geophysical Acquisition Company: CGG Data Processing Direction: 43, 44 (N to S) 93A (S to N) 93D (3D) Source Type: Vibroseis SP/VP Interval:20 m Sweep: 30-135 Hz Sweep Length: 12 s Record Length/Sample Rate: 4 s, 2 ms (1 ms for 93A+D) Source Pattern: 3 Vibrators over 18 m (93D: 250 g dynamite) Sweeps: 4 (pilot in trace 2 and 4) Instrumentation: MDS-18X Geophone Type: Mark l25D Frequency: 30 Hz Group Interval: 8 m Number of Geophones in a group: 9 Geophone Spacing: 1 m Geophone Pattern: 9 over 8 m (93D: 9 in a 1m circle) Spread Configuration (except 93D): Traces: 240----121 * 120-----1 Distances:2400-----20 20-----2400 (m)