>INFO MAXINFO=999 RUN INFORMATION REPROCESSED FROM TIME SERIES PROJECT: FR00 CLIENT: Falconbridge JOB: OPERATOR: GEOSYSTEM srl DATE: 00Sep22 TIME: 19:39:29 RUN DESC: FR01j/FR02j PROGRAM VERSION: ROBUST_CascDec LAT= 55:49:49.30 Reference Field: Remote H - Ref. XPR Weighting: RHO Variance. CUTOFF VALUE: 0.000 MAX COH VALUE: 1.000 Notch Filters set for ** Hz. Field Acquistion Parameters OPERATOR: T.Bochon ACQ DATE: 00Sep21 ACQ TIME: 16:30:00 ACQ PRGM: 0.72 Robust Processing Parameters Maximize PCOH(Ex|H)*PCOH(Ey|H) Threshold=0.90 Reject=30% STATION 1 STN Number: FR02j Site Desc: Lat 000:00:00 N Long 000:00:00 W Elevation: 0000.0 Meters. Reference Site: Site Permitted by: Permitter Site Layout by: Layout Foreman SYSTEM INFORMATION Receiver Serial Number: ADU-06 SPbox Gains: SP Box Serial Number: CMPLXON Comp C#/dB Sensor Azimuth Ex 1 0 100.0 M 0.0 DEG. Ey 2 0 100.0 M 90.0 DEG. Hx 3 0 Bf4-9724 0.0 DEG. Hy 4 0 Bf4-9714 90.0 DEG. Hz 5 0 Bf7-9717 Rx 3 0 Bf4-9724 0.0 DEG. Ry 4 0 Bf4-9714 90.0 DEG. Ex Pot Resist: K Ohms Ex Voltage:AC= mV, DC= mV Ey Pot Resist: K Ohms Ey Voltage:AC= mV, DC= mV ROTATION =