>INFO MAXINFO=4500 ------------------------------------------------------ Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L01a/R01a/ Operator:J. CURTIS Date: OCT 21 1982 Time: 11:58:07 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL32 OCT 20 1982 2 Hy1 COIL38 OCT 20 1982 3 Hz1 LOOP01 OCT 20 1982 6 Hx2 COIL01 OCT 20 1982 7 Hy2 COIL05 OCT 20 1982 8 Hz2 LOOP01 OPERATOR LOG FOR GSC-82ntv J CURTIS Cultural Factors: POWER AND GAS LINES IN GENERAL VICINITY-MINIMAL 3 KM AWAY. ALSO HIGHWAY APRX 3 KM AWAY. Weather Conditions: PARTLY CLOUDY AT RUN START GIVING WAY TO SCATTER AFTERNOON. PARTLY CLOUDY AGAIN BY RUN END.WINDS LIG RANGE 0-8 DEG C. Other Factors: EITHER RELATIVELY WEAK SIGNALS OR DEAD BATTERIES APRX 1 KM AWAY FROM SITE. SEE RUN b FOR ADDITIONA Station 1 Site Desc:None Entered Plot File:1=L01a MT Comp Chan# Sensor Azimuth Hx 1 COIL32 -10 DEG Hy 2 COIL38 +80 DEG Hz 3 LOOP01 Ex 4 70 M -10 DEG Ey 5 84 M +80 DEG Rx 6 COIL01 +0 DEG Ry 7 COIL05 +90 DEG Ex Pot Resistance: 13. K Ohms Ey Pot Resistance: 20. K Ohms Ex Voltage: AC= 4.4 mv, DC= 2.2 mv Ey Voltage: AC= 2.6 mv, DC=31.5 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: Not Entered In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L02a/R02a/ Operator:JOHN REYNOLDS/JEFF CURTIS Date: OCT 25 1982 Time: 10:38:29 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL03 OCT 20 1982 2 Hy1 COIL08 JUL 10 1982 3 Hz1 LOOP05 OCT 20 1982 6 Hx2 COIL37 OCT 20 1982 7 Hy2 COIL39 JUL 10 1982 8 Hz2 LOOP05 OPERATOR LOG FOR GSC-82ntv Operator:J CURTIS Cultural Factors: MAJOR POWERLINE 2 KM E OF SITE.ALSO GAS LINE 400 MAJOR HIGHWAY RUNNING N-S APRX 1 KM E OF SITE. Weather Conditions: PARTLY CLOUDY WITH SCATTERRED DRIZZLES.WINDS CAL Other Factors: CREEK RUNNING W-E BETWEEN LOCAL AND REMOTE STATI CULTURALLY CONTAMINATED DATA.XPR FILE 20 ALSO HAS B 5 AND 7. Station 1 Site Desc:NTS 83D/3 476879 Plot File:1=L02a MT Comp Chan# Sensor Azimuth Hx 1 COIL03 +0 DEG Hy 2 COIL08 +90 DEG Hz 3 LOOP05 Ex 4 91 M +0 DEG Ey 5 99 M +90 DEG Rx 6 COIL37 -50 DEG Ry 7 COIL39 +40 DEG Ex Pot Resistance: 1.7 K Ohms Ey Pot Resistance: 1.0 K Ohms Ex Voltage: AC=10.1 mv, DC=13.2 mv Ey Voltage: AC= 8.1 mv, DC=11.6 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: 3400 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L03a/R03a/ Operator:JOHN WINEGARDNER Date: OCT 26 1982 Time: 11:27:17 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL04 OCT 20 1982 2 Hy1 COIL33 OCT 20 1982 3 Hz1 LOOP06 OCT 20 1982 6 Hx2 COIL01 OCT 20 1982 7 Hy2 COIL32 OCT 20 1982 8 Hz2 LOOP06 OPERATOR LOG FOR Operator:J WINEGARDNER Cultural Factors: POWER LINES AND PIPELINE 2 km FROM SITE. LOGGING Weather Conditions: RAINY THROUGHOUT ENTIRE RUN. TEMP 45 deg AND CON Other Factors: VERY DENSE VEGETATION. SOIL HIGHLY ORGANIC AND H Station 1 Site Desc:NTS 83D/3 475963 Plot File:1=L03a MT Comp Chan# Sensor Azimuth Hx 1 COIL04 +0 DEG Hy 2 COIL33 +90 DEG Hz 3 LOOP06 Ex 4 90 M +0 DEG Ey 5 90 M +90 DEG Rx 6 COIL01 +0 DEG Ry 7 COIL32 +90 DEG Ex Pot Resistance: 100.K Ohms Ey Pot Resistance: 10.0K Ohms Ex Voltage: AC= 0.2 mv, DC=32.5 mv Ey Voltage: AC= 1.5 mv, DC=60.8 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: 3200 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L04a/R04a/ Operator:JEFF CURTIS Date: OCT 27 1982 Time: 11:27:28 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL05 OCT 20 1982 2 Hy1 COIL38 OCT 20 1982 3 Hz1 LOOP01 OCT 20 1982 6 Hx2 COIL03 OCT 20 1982 7 Hy2 COIL08 JUL 10 1982 8 Hz2 LOOP01 OPERATOR LOG FOR GSC-82ntv Operator:J WINEGARDNER Cultural Factors: HEAVILY TRAVELLED HIGHWAY SEPARATING SITES. TRAN PIPELINE NEAR SITE. Weather Conditions: VERY PERSISTENT RAIN THROUGH NIGHT, CLEARING AT Other Factors: Station 1 Site Desc:NTS 83M/6 518053 Plot File:1=L04b MT Comp Chan# Sensor Azimuth Hx 1 COIL05 +0 DEG Hy 2 COIL38 +90 DEG Hz 3 LOOP01 Ex 4 90 M +0 DEG Ey 5 90 M +90 DEG Rx 6 COIL03 +0 DEG Ry 7 COIL06 +90 DEG Ex Pot Resistance: 0.4 K Ohms Ey Pot Resistance: 0.6 K Ohms Ex Voltage: AC= 5.2 mv, DC=35.0 mv Ey Voltage: AC= 2.6 mv, DC=20.0 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: 2300 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L05b/R05b/ Operator:JOHN WINEGARDNER Date: OCT 30 1982 Time: 13:20:47 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL01 OCT 20 1982 2 Hy1 COIL04 OCT 20 1982 3 Hz1 LOOP05 OCT 20 1982 6 Hx2 COIL03 OCT 20 1982 7 Hy2 COIL39 JUL 10 1982 8 Hz2 LOOP05 OPERATOR LOG FOR GSC-82ntv Operator:JOHN WINEGARDNER Cultural Factors: ONLY CULTURAL FEATURE WOULD BE THE MULTIPLE HUNT PERIODICALLY. INDIVIDUAL EDITING OF XPR'S SHOUL Weather Conditions: CLEAR IN THE AFTERNOON WITH SNOW MOVING IN DURIN TEMP RANGE FROM -10 TO 0 C. Other Factors: POSSIBLE NOCTURNAL ANIMAL FORAYS. Station 1 Site Desc:NTS 83D/6 461162 Plot File:1=L05b MT Comp Chan# Sensor Azimuth Hx 1 COIL01 +0 DEG Hy 2 COIL04 +90 DEG Hz 3 LOOP05 Ex 4 83 M +0 DEG Ey 5 109 M +90 DEG Rx 6 COIL03 +0 DEG Ry 7 COIL39 +90 DEG Ex Pot Resistance: 5.5 K Ohms Ey Pot Resistance: 7.5 K Ohms Ex Voltage: AC= 0.4 mv, DC= 2.4 mv Ey Voltage: AC= 0.4 mv, DC=47.8 mv Impedance Rotation: To Strike Site Permitted by:GORDON THOMPSON Site Layout by: GORDON THOMPSON Elevation: 2600 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L06a/R06a/ Operator:J CURTIS Date: OCT 31 1982 Time: 13:43:46 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL32 OCT 20 1982 2 Hy1 COIL37 OCT 20 1982 3 Hz1 LOOP01 OCT 20 1982 6 Hx2 COIL05 OCT 20 1982 7 Hy2 COIL38 OCT 20 1982 8 Hz2 LOOP01 OPERATOR LOG FOR GSC-82ntv Operator:J CURTIS Cultural Factors: POWER AND GAS LINES IN VICINITY.MAJOR HIGHWAY RU SITE.ALSO FAIRLY HEAVY DAYTIME TRAFFIC ON DIRT ROAD BOTH STATIONS(HUNTING SEASON). Weather Conditions: MOSTLY OVERCAST SKIES WITH SCATTERED SHOWERS AND MODERATE.TEMP RANGE 0 TO 10 DEG C. Other Factors: PHASE WRAP-AROUND EFFECT ON LOWER RHO MAG CURVE AND IS CONSISTENT WITH SITES 04 AND 05. Station 1 Site Desc:NTS 83D/11 560245 Plot File:1=L06a MT Comp Chan# Sensor Azimuth Hx 1 COIL32 +0 DEG Hy 2 COIL37 +90 DEG Hz 3 LOOP01 Ex 4 50 M +0 DEG Ey 5 49 M +90 DEG Rx 6 COIL05 +0 DEG Ry 7 COIL38 +90 DEG Ex Pot Resistance: 8.4 K Ohms Ey Pot Resistance: 5.2 K Ohms Ex Voltage: AC=1.1 mv, DC=54.0 mv Ey Voltage: AC=0.9 mv, DC=18.2 mv Impedance Rotation: To Strike Site Permitted by:P CARTWRIGHT Site Layout by: G THOMPSON Elevation: 3100 FT In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L07a/R07a/ Operator:JOHN WINEGARDNER Date: NOV 02 1982 Time: 03:30:03 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL37 OCT 20 1982 2 Hy1 COIL38 OCT 20 1982 3 Hz1 LOOP01 OCT 20 1982 6 Hx2 COIL05 OCT 20 1982 7 Hy2 COIL32 OCT 20 1982 8 Hz2 LOOP01 OPERATOR LOG FOR GSC-82-L0 Operator:JW,JC, & JR Cultural Factors: SITES LOCATED PARALLEL TO THREE POWER LINES, A R A MAJOR HIGHWAY AT A DISTANCE OF 500m. SMALL SI SOUTH OUT OF VALEMONT CAUSED LARGE PROBLEMS WITH Weather Conditions: CLEAR AND COLD TEMP -20 TO 0 C. Other Factors: Station 1 Site Desc:NTS 83D/11 527343 Plot File:1=L07a MT Comp Chan# Sensor Azimuth Hx 1 COIL37 -6 DEG Hy 2 COIL38 +84 DEG Hz 3 LOOP01 Ex 4 59 M -6 DEG Ey 5 65 M +84 DEG Rx 6 COIL05 +0 DEG Ry 7 COIL32 +90 DEG Ex Pot Resistance: 22.0K Ohms Ey Pot Resistance: 20.0K Ohms Ex Voltage: AC= 4.7 mv, DC=11.9 mv Ey Voltage: AC=38.4 mv, DC=13.5 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: 3000 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L08/R08a/ Operator:JOHN WINEGARDNER Date: NOV 01 1982 Time: 11:38:28 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL03 OCT 20 1982 2 Hy1 COIL04 OCT 20 1982 3 Hz1 LOOP05 OCT 20 1982 6 Hx2 COIL01 OCT 20 1982 7 Hy2 COIL39 JUL 10 1982 8 Hz2 LOOP05 OPERATOR LOG FOR GSC-82-L0 Operator:J WINEGARDNER Cultural Factors: POWER LINES AND MAJOR HIGHWAY 500m FROM REMOTE. Weather Conditions: PARTIALLY CLOWDY, CLEARING IN MIDDLE OF RUN. TEM TO 40 DEG f. Other Factors: Station 1 Site Desc:NTS 83D/14 486468 Plot File:1=L08a MT Comp Chan# Sensor Azimuth Hx 1 COIL03 +0 DEG Hy 2 COIL04 +90 DEG Hz 3 LOOP05 Ex 4 69 M +0 DEG Ey 5 114 M +90 DEG Rx 6 COIL01 +0 DEG Ry 7 COIL39 +90 DEG Ex Pot Resistance: 5.0 K Ohms Ey Pot Resistance: 5.0 K Ohms Ex Voltage: AC= 8.6 mv, DC=65.0 mv Ey Voltage: AC= 6.4 mv, DC=21.0 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: 2600 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L09/R09a/ Operator:JOHN WINEGARDNER Date: OCT 28 1982 Time: 22:06:52 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL05 OCT 20 1982 2 Hy1 COIL39 JUL 10 1982 3 Hz1 LOOP05 OCT 20 1982 6 Hx2 COIL01 OCT 20 1982 7 Hy2 COIL04 OCT 20 1982 8 Hz2 LOOP05 OPERATOR LOG FOR GSC-82-L0 Operator:JOHN WINEGARDNER Cultural Factors: TRANSMISSION LINES SEVERAL Km's AWAY ALSO HIGHWA Weather Conditions: CLEAR AND COLD (5-25 DEG f.) WET GROUND FROM PRE Other Factors: NONE Station 1 Site Desc:NTS 82M/14 379633 Plot File:1=L09a MT Comp Chan# Sensor Azimuth Hx 1 COIL05 +0 DEG Hy 2 COIL39 +90 DEG Hz 3 LOOP05 Ex 4 90 M +0 DEG Ey 5 90 M +90 DEG Rx 6 COIL01 +0 DEG Ry 7 COIL04 +90 DEG Ex Pot Resistance: 3.5 K Ohms Ey Pot Resistance: 1.1 K Ohms Ex Voltage: AC=17.4 mv, DC=38.5 mv Ey Voltage: AC= 7.1 mv, DC=57.0 mv Impedance Rotation: To Strike Site Permitted by:PAUL CARTWRIGHT Site Layout by: GORDON THOMPSON Elevation: 3600 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 Run Information Project:N. THOMPSON VALLEY Client :G. S. of CANADA Run:GSC-82-L10/R10a/ Operator:JEFF CURTIS Date: OCT 29 1982 Time: 13:58:12 Program Version:MTS-A4 Latest Revision:SEP 29 1982 Reference Field: 5 = Special Ref XPR Weighting: 2 = Rho Variance XPR Record Int: 30 Min Sensor Box Gains:E's - x1 H's - x1 Notch Filters: 60,180,300 Hz System Calibration BRITISH COLUMBIA SP CAL By WINEGARDNE Date: OCT 20 1982 File: C#1 Sensor Calibration Chan# Chan Sensor Cal Date 1 Hx1 COIL32 OCT 20 1982 2 Hy1 COIL37 OCT 20 1982 3 Hz1 LOOP01 OCT 20 1982 6 Hx2 COIL05 OCT 20 1982 7 Hy2 COIL38 OCT 20 1982 8 Hz2 LOOP01 OPERATOR LOG FOR GSC-82-L1 Operator:J CURTIS Cultural Factors: POWER AND GAS LINES IN VICINITY. ALSO MAJOR HIGH PARALLEL TO THE POWER AND GAS LINES. Weather Conditions: MOSTLY CLEAR SKIES. NO WIND. TEMP RANGE -10 TO 0 Other Factors: 6-9 INCHES SNOW COVERING SITE VICINITY. Station 1 Site Desc:NTS 82M/14 355500 Plot File:1=L10a MT Comp Chan# Sensor Azimuth Hx 1 COIL32 +0 DEG Hy 2 COIL37 +90 DEG Hz 3 LOOP01 Ex 4 101 M +0 DEG Ey 5 98 M +90 DEG Rx 6 COIL05 +0 DEG Ry 7 COIL38 +90 DEG Ex Pot Resistance: 3.5 K Ohms Ey Pot Resistance: 9.5 K Ohms Ex Voltage: AC= 4.9 mv, DC=27.6 mv Ey Voltage: AC= 2.1 mv, DC=38.2 mv Impedance Rotation: To Strike Site Permitted by:GORDON THOMPSON Site Layout by: GORDON THOMPSON Elevation: 5100 In this file it is assumed that the magnetic sens are arranged in a fixed location with respect to th REFLAT and REFLONG in the file. SENSOR X(m) Y(m) Hx 17 17 Hy -17 17 Hz 17 -17 RHx 1280 1270 RHy 1270 1280 Ex calculated (centred on REFLAT, REFLO Ey calculated (centred on REFLAT, REFLO REx 1225-1325 1275 REy 1275 1225-1325 ------------------------------------------------------